MetSorb™ HMRG (Heavy Metal Removal Granules)
Highly Effective, Low-Cost Adsorbent for Reduction of Arsenic III & V
and a Wide Variety of Heavy Metals
|
MetSorb HMRG and HMRP adsorbents utilize a patented material to adsorb both forms of arsenic as well as a wide range of contaminants in water. Empty bed contact times as low as 10 seconds achieve high removal efficiencies. The material affords a higher capacity and a lower level of ion interference than competitive iron and alumina based products.
MetSorb HMRG media’s adsorptive capacity is 220 grams of arsenic per kilogram of HMRG adsorbent at a pH of 7. It yields 40,000 bed volumes of capacity at an inlet concentration of 40 parts per billion (ppb) of arsenic, at 1.6 minutes of empty bed contact time (EBCT), and a breakthrough of 10 ppb.
Adsorbent Product Features/Benefits
| » |
Removal of heavy metals to meet drinking water standards |
| » |
High adsorbent capacity requiring less frequent replacement |
| » |
Fast kinetics to work effectively at high flow rates |
| » |
Nonhazardous disposal as solid waste |
Contaminants
| • |
Arsenic III |
| • |
Arsenic V |
| • |
Cadmium |
| • |
Copper |
| • |
Antimony |
| • |
Lead |
| • |
Mercury |
| • |
Uranium |
| • |
Zinc |
| • |
Selenium |
|

| MetSorb HMRG Adsorbent Specifications |
|
HMRG Granular |
| Appearance |
White beads |
| Moisture Content |
<10% |
| Bulk Density |
0.65 grams per millimeter
(40 lb/ft3) |
| Other |
Free Flowing |
| Particle |
-16+ 60 U.S. mesh
(other sizes available) |
|
Applications
| • |
Commercial and industrial treatment units for drinking water or contaminated water |
| • |
Municipal water treatment |
| • |
Carbon blocks |
| • |
Cartridges for pitchers |
| • |
Faucet mounted and counter top devices |
| • |
Household point of entry treatment units |
|
Comparison of HMRG adsorbent with
iron-based adsorbent.
|
|
|
Treatment capacity as a function of tank size. |
Testing was done under the conditions specified by the NSF Standard 53 for Arsenic. Results at a pH of 6.5 and a pH of 8.5 are shown in the graph above.
|
 Lead removal by MetSorb HMRG adsorbent in column test; 30 seconds EBCT. |
 Adsorption isotherms for lead between pH 5 and 7
are nearly identical. |
The above graph shows the adsorption isotherm for Arsenic V at pH 8.5 Isotherms for Arsenic III at pH 8.5, and for both forms of Arsenic at pH 4 are essentially identical.
|